- AUTO_DIALING, LOUD SPEAKING, LIFT
INTERCOM SYSTEM - EASY ADDRESSING OF STATIONS VIA DIP_SWITCH
- DESIGNED TO MEET EN 81-28 STANDARDS
- SELF DIAGNOSTICS AND EVENT REPORTING TO EMFONE REMOTE PHONE MONITORING & P100 MONITORING STANDARDS (EN81/28)
BUILT IN BATTERY BACK UP SYSTEM- FULLY PROGRAMMABLE
- ROBUST INDUSTRY PROVEN PEER TO PEER SINGLE CABLE INTERFACE (DATA & POWER)
- INTERNAL INTERCOM WILL ALLOW COMMUNICATIONS BETWEEN ANY STATION, INCLUDING GROUP PAGES
- HANDS FREE LOUDSPEAKER WITH VOLUME CONTROL
- I/O INTERFACE WITH PROGRAMMABLE OUTPUTS CONTACTS & ALARM FILTERING OPTIONS TO REDUCE NUISANCE CALLS
BUILT IN STATION LED’S FOR CALL STATUS NOTIFICATIONS- THREE TELEPHONE NUMBER DIALLING CAPABILITY
- TELEPHONE LINE & POWER SUPPLY FAULT DIAGNOSIS WITH LIFT VOICE ALERT
- VOICES RECORDING TO IDENTIFY CALLING LOCATION
- EASE PROGRAMMING FUNCTIONS VIA REMOTE MOBILE/HANDSET WITH VOICE FEEDBACK & VERIFICATION OF ACTIONS
- FULLY COMPATIBLE WITH ALL TYPES OF PHONE SYSTEMS
- CASCADE UP TO 4 LIFTS (SYSTEM) IN CONJUNCTION WITH THE PIXEL GATEWAY
The compact design of the emFONE 181 system, allows both emergency and internal communications throughout a single lift shaft. Supporting up to eight stations it provides users with a high-quality hands-free solution, be it from the motor room or MRL cabinet to the top of a car, in car and pit stations. The em-181 has a built-in battery backup of up to 8 hours standby and 4 hours talk time in a typical installation.
The in-car station allows for a compact flush mount all in one design or external speaker and microphone mounting options. All stations include additional I/O ports allowing a secure connection to other peripherals such as elevator call buttons and LED call status notifications. The robust and industry-proven peer to peer single cable interface (Data & Power) allows a maximum of 400 meters of cabling per lift without the loss of audio quality. All programming functions and features are done by simply dialling into the master unit from a remote handset or mobile phone.
OPERATION | DETAILS |
Input Voltage | 18V DC – 28VDC |
Standby Current | Charging 0.35A / Charged 0.20A @ 18V DC |
Operating Current | Charging 1A / Charged 0.31A @ 18V DC |
Input Voltage | 18V DC – 28V DC |
Data BUS | Peer to Peer Single Wire Data BUS Length: 400M (max) |
Recommended cable | Beldin 8723 (2 x twisted shielded pair cable) |
Maximum Stations | 8 (addressable) |
Operating Current | Page All-1A@18V, Alarm Call-0.31A@18V |
Voice Message | Programmable Voice identification (16 Seconds Max) |
Help Number | 8 Numbers (16 Digits Max) |
Alarm Filter Input | Dry contact |
Outputs | Open Collector 24V @ 100mA (Master) / 150mA (Station) |
Battery Type | 12V SLA 0.8Ah |
Typical Battery Backup | 8 Hours standby / 4 Hours operating |
Operating Temp | 0deg c – 50deg c |
The emFONE CD-LX8 System is an auto-dialing lift intercom system designed to save both time and money in all aspects of the installation.
- AUTO DIALLING LIFT INTERCOM SYSTEM
- BUILT IN AUTO SCAN & DETECT
- MEETS EN81-28 STANDARDS
- EVENT REPORTING TO CONTROL CENTRE
- BACKUP BATTERY SYSTEM
- FULLY PROGRAMMABLE
- ROBUST 4 WIRE BUS, UP TO 32 STATIONS
- COMMUNICATE BETWEEN ANY STATION
- HANDSFREE LOUDSPEAKER
- PROGRAMMABLE OUTPUT RELAYS
- ALARM ALTERING OPTION
- VOLUME CONTROL
The emFONE LX System is an auto-dialing lift intercom system designed to save both time and money in all aspects of the installation. A single telephone line can be shared by up to 32 intercom stations and a robust 4-wire bus arrangement allows simple cabling solutions avoiding the need to run individual wires to each intercom station.
The system will dial out to the lift company using the single external line connected to the master, identifying the lift no and location of the call. The unit can be programmed to then automatically dial out to building management following the call to the lift company.
The system will help a person unable to communicate with the service provider, either because of a physical disability or language difference. A remote programmable digital voice message, of up to 16 seconds, is played upon answer of the call, and is used to identify the calling location to service provider.
The lift company can ring into the system and select any lift car or intercom station to communicate with or if necessary talk to all intercom stations by a group page.
OPERATION | DETAILS |
Operating Voltage | 110V AC -240V AC, 50HZ |
Operating Current | 60mA (Standby) 350mA (Operating) |
Telephone Line Voltage | 24V – 50V DC |
Telephone Line Current | 10mAm – 90mA |
Dialling Method | Tone (DTMF) |
Backup Battery System | Lead Acid – operating life of 3 years minimum |
Battery Operating Time | 8 hours Standby; 4 hours Full Operation |
Digital Voice Message | Non Erasable Memory – 100 year message retention & 100,000 record cycles |
Message Length | 16 seconds, user programmable remotely |
Cable | Paired wire 2 off |
PRODUCT | MODEL / DETAILS | |
CD-LX8/M
Lift Intercom Master Unit |
||
CD-LX/SK
Builders Lift Intercom |
||
CD-LX/SL
Keypad With Internal Speaker and Microphone |
||
CD-LX/SLX
Keypad With External Speaker & Microphone |
- IP COMMUNICATION
- EXPANDABLE SYSTEM
- LINE INTERFACE
- 4GE VOLTE REDUNDANCY
- WEBSERVER CONFIGURABLE
- SINGLE PAI ETHERNET
- REMOTE MANAGEMENT
- MONITORING
- BATTERY BACKUP
- CONNECTION TO 5 LIFTS
- 2 RJ-45 ETHERNET PORTS
- 4 x PIXEL MPCLE MODULE
- ALARM ADJUST
- ALARM CALL ROUTING
- VOICE IDENTIFICATION
- CALL QUEUEING
- 8 INTERCOM STATIONS
- 4-WIRE CONNECTIVITY
- RGB LED STATUS
- HANDS FREE LOUD SPEAKER
- NETWORK AUTO DETECT
- CALLER ID
- PAGING OPTIONS
- LCD KEYPAD MENU
With Ethernet integration into managed building networks, 2-wire connectivity for easy upgrades, remote management and monitoring of all devices, this system offers flexible and redundant alarm call routing options. Additionally, the battery backup system ensures that your lifts are always covered.
PRODUCT | MODEL / DETAILS | |
CD-LX/C Control Console |
||
CD-LX1/MD Machine Room Master |
||
CD-LX/SK Builders Lift Intercom |
||
DE-1 Help Point Intercom |
||
CD-LX/SL
Keypad With Internal Speaker and Microphone |
||
CD-LX/SLX
Keypad With External Speaker & Microphone |
Digital IP Communication System Brochure 2.09 MB 462 downloads
…
Communication and emergency response is the most vital requirement of any building site. For this reason we have developed a reliable and easy to use product designed and perfected to maintain communication between construction workers.
- TALK FROM LANDING TO LIFT CAR
- TALK FROM LIFT CAR TO LANDING
- COMMUNICATE BETWEEN MULTIPLE LIFTS
- SINGLE/DUPLEX CAR CAPABILITIES
- TRIPLEX/HOIST CAR CAPABILITIES
- HIGH QUALITY COMMUNICATIONS
- LOW VOLTAGE POWERED SYSTEM
- PROGRAM MULTIPLE NUMBERS
- COMMUNICATE FROM JOB SITE TO CAR
The emFONE Builders Lift Intercom offers the complete solution to any new building site. The system offers a crystal clear communication path between any landing station and the elevator / hoist master device, allowing one to one or one to all communication throughout.
With the capability to connect up to 3 separate lifts / hoists the user on each landing can decide exactly which lift / hoist they want to talk to. The operator in the lift / hoist can then choose to “talk back” which will open a path back to the station that called them.
All units come with the additional safety call buttons of FIRST AID & SITE OFFICE. When pressed for 5 seconds these buttons will initiate an emergency call back to the first Aid officer or site office. Multiple numbers can be programmed into the system to ensure the call is answered.
OPERATION | DETAILS |
Operating Voltage | 18V DC |
Data Bus | P2P Single Wire |
Station Data Bus Nodes |
78 Stations (max) |
Signal | 600 Ohm Impedance |
Speaker Level |
80dB (max) |
Microphone | Adjustable – 5m Range |
Operating Temperature | 0°C – 50°C |
PRODUCT | MODEL / DETAILS | |
CD-BI/SC Car Station Intercom |
||
CD-BI/SL Landing Station Intercom |
||
CD-BI/TE Trailer Cable Termination Board |
||
CD-BI/PSU Power Supply |